电阻测量装置通用技术条件第1部分:电子式绝缘电阻表General specifications for measuring resistance equipmentsPart1: electronic insultion resistance metere2004-03-05发布 2004-06-01实施中华人民共和国国家发展和改革委员会 发布
目 次
前言·······································································································································
1 范围·································································································································
2 规范性引用文件·············································································································
3 术语和定义·····················································································································
4 分类·································································································································
5 技术要求·························································································································
6 试验方法·························································································································
7 检验规则·························································································································
8 标志、包装、运输、贮存·····························································································
本标准根据原国家经济贸易委员会电力司《关于确认1999年度 电力行业标准制、修订计划项目的通知》(电力[2000]22号)下达的《电阻测量装置通用技术条件》标准项目制定。
DL/T845《电阻测量装置通用技术条件》本次发布以下四个部分:
本部分为DL/T845《电阻测量装置通用技术条件》的第1部分。
本标准参加起草单位:武汉市康达电气有限公司、北京海淀三鑫测控新技术公司。
本部分主要起草人:黄卫民、梁涛、蔡崇积、李心恕、胡学军、古龙华。
DL/T 845 的本部分规定了电子式绝缘电阻表(以下简称绝缘表)的术语和定义、分类、技术要求、试验方法、检验规则和标志、包装、运输、贮存。
本部分适用于在额定值不超过 lOkV的直流电压作用下,用电子方式测量并直接显示所测绝缘电阻值的电子式绝缘电阻表。
下列文件中的条款通过DL/T845的本部分的引用而成为本部分的条款。凡是注日期的引用文件,其随后所有的修改单 (不包括勘误的内容)或修订版均不适用于本部分,然而,鼓励根据本部分达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本部分。
GB 191 包装储运图示标志 EQV ISO 780: 1997
GB4793.1—1995 测量、控制和试验室用电气设备的安全要求 第1部分:通用要求 IDT ICE 61010—1:1990
GB/T 6587.8 电子测量仪器 电源频率与电压试验
GB/T 7676.1—1998 直接作用模拟指示电测量仪表及其附件 第1部分:定义与通用要求 IDT IEC 60051—1:1984
GB/T 7676.9—1998 直接作用模拟指示电测量仪表及其附件 第9部分:推荐的试验方法 IDT IEC 60051—9:1988
电子式绝缘电阻表 electronic insultion esistance meters
绝缘表中用于连接被测对象的接线端子。测量端子接其与被测对象的连接部位,
开路电压 open-circuit voltage
绝缘表的测量线路的端子L与接地端子E之间连接被测对象,测量其绝缘电阻时的端电压值。
输出短路电流 output short-circuit current
绝缘表测量线路端子L与接地端子E短路时,接地端子E的输出电流。
工作电压建立时间 setting time for working voltage
绝缘表测量绝缘电阻时,其端电压值从零上升到额定电压值的90%以上的稳定工作电压值所需 时间。
残余电荷泄放时间 bleed-off time for residual charge
绝缘表测量结束,关断绝缘表端电压控制开关时,其端电压从测量时的端电压值(工作电压)下降到60V所需的时间。
影响量的规定值和规定范围的一个适当集合,在此条件下规定仪表和或附件允许误差。每个影响量均可有参比值或参比范围。
标称使用范围 nominal rnge of use
对影响量规定的一个取值范围。在此范围内影响量所引起的改变量不超出规定值。
当一个单一影响量相继取参比条件的规定值和标称使用范围内任一的值时,分别测量同一个量值的测量误差的最大差值(不考虑符号)。
50,100,250,500,1000,2000,2500,5000,10000V。
10,20,50,100,200,500,1000,2000,2500,5000MΩ;
10,20,50,100,200,500,1000GΩ。
0.2,0.5,1.0,2.0,5.0,10.0,20.0。
按标称使用范围(工作范围)分类,绝缘表分为11组、皿组与1级、2级、3级。(按GB/T 6587.1规定的标称使用范围(工作范围)及通流条件)。
个别影响量的标称使用范围(工作范围)可以低于规定组别的要求,但需符合企业标准规定,并在产品使用说明书标明。鼓励企业标准比规定组别的要求更严。
按被测量的显示(指示)方式分类,绝缘表分为模拟式和数字式。
注只涉及被测量的输出或显示的表示形式而与仪表的工作原理无关。
绝缘表的外表应整洁美观,不应有变形、缩痕、裂纹、划痕、剥落、锈蚀、油污、变色等缺陷。文字、标志等应清晰无误。
绝缘表的控制调节机构和指示装置应运行平稳,无阻滞和抖动现象。
绝缘表的安全性能应符合GB 4793.1的有关规定。
c)供电电源:化学电源:(额定值±0.2)V;交流电源:(220±4)V,(50±0.5)Hz;
模拟式绝缘表可以将测量范围划分为高准确度区段和低准确度区段。两区段之间应有分界标记或/和在使用说明书上注明其分界处的量值。高准确度区段的长度不得小于标度尺长度的50%。
在参比条件下,在规定的测量范围内,模拟式绝缘表的基本误差应不超过表1规定的极限值。
表1 模拟式绝缘表基本误差极限值
模拟式绝缘表准确度等级 |
0.2 |
0.5 |
1.0 |
2.0 |
5.0 |
10.0 |
20.0 |
基本误差极限值% |
高准确度区段 |
±0.2 |
±0.5 |
±1.0 |
±2.0 |
±5.0 |
±10.0 |
±20.0 |
低准确度区段 |
±0.5 |
±1.0 |
±2.0 |
±5.0 |
±10.0 |
±20.0 |
±50.0 |
在参比条件下,在规定的测量范围内,数字式绝缘表的基本误差不超过按公式(1)计算的基本误差极限值。公式(1)中,变换系数a,固定误差b的值按表2确定。
能同时模拟指示与数字显示的绝缘表应确定其中一种显示万式的示值符合规定的准确度等级。二种显示方式的示值之差不得超过该准确度等级所确定的误差极限值。
表2 数字式绝缘表变换系数和固定误差值
数字式电子绝缘电阻表准确度等级 |
0.2 |
0.5 |
1.0 |
2.0 |
5.0 |
10.0 |
20.0 |
变换系数 |
0.2 |
0.5 |
1.0 |
2.0 |
5.0 |
10.0 |
20.0 |
固定误差 |
1 |
1 |
2 |
2 |
2 |
4 |
4 |
注: ——显示值最末位数的1个单位所对应的量值。 |
绝缘表的开路电压与额定电压之差不大于额定电压的±10%。
绝缘表的测量线路端子L与接地端子E间连接阻值为测量范围上限值的5的电阻时,其输出工作电压与额定电压之差不大于额定电压的±10%。
在lmin内,绝缘表的开路电压的最大值与最小值的差应不大于额定电压的±5%。
绝缘表的输出短路电流应不小于0.1,0.2,0.3,0.5,0.6,0.8,1,1.2,1.5,2,2.5,3,4,5,8,l0mA序列中的一确定值。
由干电池供电的绝缘表,当因电源电压变化使绝缘表的准确度等级可能改变时,应给出相应的电源电压指示或警告标志。
绝缘表的接地端子E应为正极性,测量线路端子L应为负极性。
测量范围上限值大于500MΩ的绝缘表应有防止测量电路泄漏电流影响的屏蔽装置和独立的屏蔽端子。
分别在测量线路端子L与屏蔽端子G之间和接地端子E与屏蔽端子G之间各接入一个阻值为绝缘表的额定电压与0.05mA之比的电阻时,绝缘表的准确度等级不致改变。
测试中,测量端子间短路与开路,绝缘表均不致损坏,其准确度等级不致改变。
绝缘表的测量端子间应能耐受其值为工作电压值的电容性负载上的残余电压的冲击。经该残余电压冲击后,绝缘表的准确度等级不致改变。
由化学电源供电的绝缘表,当电源电压为其标称使用范围上、下限值而引起的改变量;或由交流电源供电的绝缘表,当电源电压为(220±22)V,频率为(50±2.5)Hz时而引起的改变量,不应使绝缘表的基本误差超过其基本误差极限值。
绝缘表的工作位置偏离规定的标准位置5。而引起的改变量应不超过其基本误差极限值的50%。
注:数字式绝缘表和装有水准器的绝缘表,不必进行由位置变化而引起的改变量的试验。
绝缘表按4.4规定的组别进行温度、湿度、振动、冲击和运输试验而引起的改变量均不应超过绝缘表的基本误差极限值。且试验后还应符合5.4、5.5、5.6、5.7、5.8、5.10的规定。
绝缘表的平均无故障工作时间(MTBF)不小于1000h。
在5.3.1的参比条件下,用标准高压电阻箱作标准器,按JJG 622—1997的15.1.2、15.1.8及15.2的条件进行试验。
模拟式绝缘表在其测量范围内每个有分度数字的分度线处检测。
数字式绝缘表在其测量范围内均匀选取至少10个电阻值(包括测量范围上限值、下限值或其附近的值)处进行检测。
同时具有模拟指示与数字显示的绝缘表在模拟式绝缘表所检测的分度线处检测。
将标准器按图1所示方式与绝缘表连接。调节标准器,使绝缘表的示值依次为按6.3.2确定的值BX,记录相应标准器的对应值BR。
R—标准电阻;E—接地端子;L—测量线路端子;G—屏蔽端子图1 检测基本误差接线图
端电压采用准确度不低于1.5级的静电电压表检测,也可以采用输入阻抗足够大,准确度不低于1.5级的直流高压测试装置检测。
对于额定电压不小于2 000V、测量范围上限值不小于20GΩ的绝缘表,在其测量线路端子L与接,地端子E之间并联连接无极化的试验电容器和试验电阻器,试验电容器的容量为0.1 F,试验电阻器的阻值可在1,2,5,10,20GΩ序列中选取。计时的起始时刻为端电压值为零时;计时的终止时刻为端电压上升到其额定电压的90%以上的一个稳定值时,此时绝缘表的示值误差不超过其误差极限值(不计试验电容器的绝缘电阻引入的误差)。记录从起始时刻到终止时刻的时间即为工作电压建立时间,该时间应满足5.5要求。
监测端电压的电压表的响应时间应足够小,必要时可扣除电压表的响应时间。
在6.5试验结束后,关断绝缘表端电压控制开关时,记录其端电压从测量时的端电压值(工作电压)下降到60V所需的时间。该时间应满足5.6要求。
按5.7,用准确度不低于1.5级的直流电流表检测。
按5.8,用可调直流稳压电源供电,用准确度等级不低于1.5级的直流电压表检测。
按5.10,在测量范围的上限值、下限值及中点值或附近处检测其基本误差。
测量端子L、E之间短路、开路各5次,每次短路的时间约2s,开路的时间约5s。试验后,在测量范围上限值、下限值及中点值或附近处检测其基本误差。
将容量为0.1 F,其端电压己被充电至绝缘表工作电压值的标准试验电容器中贮存的电荷分别经绝缘表的测量端子L与G之间和L与E之间放电。然后,在测量范围上限值与下限值或其附近处检测其基本误差。
化学电源供电的绝缘表,按GB何7676.9中3.11进行试验。
交流电源供电的绝缘表,按GB何6587.8进行试验。
按检验项目,绝缘表的缺陷分为A、B、C三类。A类为致命缺陷,缺陷等级数为l;B类为重缺陷,缺陷等级数为0.6;C类为轻缺陷,缺陷等级数为0.2。检验项目的缺陷类别见表3。
检验样本中,有缺陷检验项目的缺陷等级数之和小于1时判该样本合格;有缺陷检验项目的缺陷等级数之和不小于1时判该样本不合格。
鉴定检验在产品定型时进行。当绝缘表的主要设计、工艺、材料及元器件等有重大变更时或停产后恢复生产时也应进行鉴定检验。
检验中按7.3判别样本。样本全部合格,且现场使用试验合格方可判定鉴定检验合格。
鉴定检验结论对设计相同、规格不同的绝缘表均有效。应对出现缺陷可能性最大的那类绝缘表进行鉴定检验。检验中,出现故障,允许修复后再继续检验。
质量一致性检验在正式生产时进行,以判定所提交的绝缘表的质量是否符合产品标准的要求。
批量生产时,按表3的检验项目进行A组、B组、C组、F组检验。非成批生产时,按表3中序号1~11的检验项目进行全数检验,其合格判据按7.3。
A组检验是对生产的全部产品或一个检验批中的全部样本所进行的非破坏性试验。每批产品均按表3中A组检验规定的项目全数检验。样本的合格判据按7.3。
进行A组检验的批,其批质量以每百台的不合格品数表示。
序号 |
检验项目 |
本标准条款 |
缺陷等级 |
鉴定检验 |
质量一致性检验 |
技术要求 |
试验方法 |
A组 |
B组 |
C组 |
D组 |
1 |
外观与结构 |
5.1 |
6.1 |
C |
√ |
√ |
|
|
|
标志 |
8.1 |
6.1 |
C |
√ |
√ |
|
|
|
2 |
安全要求 |
5.2 |
6.2 |
A |
√ |
|
√ |
|
|
3 |
基本误差 |
5.3.2 |
6.3 |
A |
√ |
√ |
|
|
|
4 |
开路电压 |
5.4 |
6.4 |
B |
√ |
√ |
|
|
|
工作电压 |
5.4 |
6.4 |
B |
√ |
√ |
|
|
|
电压稳定性 |
5.4 |
6.4 |
C |
√ |
|
√ |
|
|
5 |
工作电压建立时间 |
5.5 |
6.5 |
C |
√ |
|
√ |
|
|
电荷自泄放时间 |
5.6 |
6.6 |
C |
√ |
|
√ |
|
|
6 |
输出短路电流 |
5.7 |
6.7 |
B |
√ |
|
√ |
|
|
7 |
电源电压指示 |
5.8 |
6.8 |
C |
√ |
√ |
|
|
|
8 |
测量端钮 |
5.9 |
6.9 |
A |
√ |
√ |
|
|
|
9 |
屏蔽装置 |
5.10 |
6.10 |
B |
√ |
|
√ |
|
|
10 |
耐短路、开路 |
5.11 |
6.11 |
C |
√ |
|
√ |
|
|
11 |
耐电压冲击 |
5.12 |
6.12 |
C |
√ |
|
√ |
|
|
12 |
供电电源影响 |
5.13 |
6.13 |
B |
√ |
√ |
|
|
|
位置影响 |
5.14 |
6.14 |
B |
√ |
|
√ |
|
|
13 |
温度试验 |
5.15 |
6.15.1 |
B |
√ |
|
|
√ |
|
湿度试验 |
5.15 |
6.15.2 |
B |
√ |
|
|
√ |
|
振动试验 |
5.15 |
6.15.3 |
B |
√ |
|
|
√ |
|
冲击试验 |
5.15 |
6.15.4 |
B |
√ |
|
|
√ |
|
运输试验 |
5.15 |
6.15.5 |
B |
√ |
|
|
√ |
|
14 |
可靠性试验 |
5.16 |
6.16 |
|
|
|
|
|
√ |
15 |
现场使用试验 |
|
|
|
√ |
|
|
|
|
每百台不合格品数不大于5的批,其批产品A组检验合格。A组检验中应对发现有缺陷的样本单位返修,合格后可以交货。
每百台不合格品数大于5的批,其批产品A组检验不合格。判为不合格的批,整批退回生产单位,找出原因,予以返修,重新检验。
B组检验是对产品中较少受到工艺影响的性能特性实施的逐批检验。
在A组检验合格的产品批中,按GB/T 6593—1996中5.2.2.1抽样。按表3中B组检验的项目检验样本。检查水平S—3,合格质量水平AQL=6.5,合格判定按7.3与GB/T6593中5.2.2.2。
在B组检验合格的产品批中,随机抽取3台。按表3中C组检验的项目进行试验。检验中,按7.3判别样本。样本全部合格,判定C组检验合格。试验过程中,出现故障允许修复后再检验。
C组检验,每年或每生产一定数量绝缘表进行一次。或在设计、工艺有重大改变,有可能使产品性能不符合产品标准时进行。
绝缘表的测量端子旁应分别标出测量线路端子、接地端子、屏蔽端子的标志符号:L、E、G。
额定电压大于lkV的绝缘表,其测量线路端子L旁应有“当心电击危险”警告符号。其标志图样应符合GB 4793.1—1995表1的图形符号12。
a)准确度等级标志,其标志图样应符合GB/T7676.1—1998表III一1中符号E—3;
b)水平使用或垂直使用标志,其标志图样应符合GB/T7676.1—1998表III-1中符号D-1或符号D-2;
b)“易碎物品”、“向上”、“怕雨”等标志,标志图样应符合GBl91的规定;
绝缘表的包装应能防振、防潮。能使绝缘表经受5·15规定的运输试验而不致损坏。包装箱内应有:
绝缘表经包装后可用车、船、飞机等交通工具运输。但应避免暴晒、雨淋、水浸、跌落、撞击与机械损伤。
绝缘表可贮存在温度为-10℃~+50℃(II组)或-40℃~+60℃(III组),相对湿度不大于90%、无腐蚀性气体、通风良好的库房内。
中华人民共和国电力行业标准DL/T 845.2—2004
电阻测量装置通用技术条件第2部分:工频接地电阻测试仪General specifications for measuring resistance equipmentsPart2: power frequency earth resistance testers2004-03-05发布 2004-06-01实施中华人民共和国国家发展和改革委员会 发布目 次
前言··········································································································································
1 范围····································································································································
2 规范性引用文件················································································································
3 术语和定义························································································································
4 分类····································································································································
5 技术要求····························································································································
6 试验方法 ··························································································································
7 检验规则····························································································································
8 标志、包装、运输、贮存································································································
前 言
本标准根据原国家经济贸易委员会电力司《关于确认1999年度电力行业标准制、修订计划项目通知》(电力陀叨0)22号)下达的《电阻测量装置通用技术条件》标准项目制定。
DL/T845《电阻测量装置通用技术条件》本次发布以下四个部分:
本部分为DU/T845《电阻测量装置通用技术条件》的第2部分。
本部分主要起草人:李滑森、梁涛、蔡崇积、陈晓燕、胡学军。
电阻测量装置通用技术条件第2部分:工频接地电阻测试仪
DL/T 845的本部分规定了工频接地电阻测试仪(以下简称地阻仪)的术语和定义、分类、技术要求、试验方法、检验规则和标志、包装、运输、贮存。
本部分适用于通过电流极注入测试电流,通过电压极获得相关的电位,能直接显示测量值的接地电阻测试仪。
本部分不适用于手摇发电机供电的接地电阻测试仪。也不适用于特殊用途的接地电阻测试仪,如防爆式接地电阻表、冲击接地阻抗测量装置等。
下列文件中的条款通过DL/T 845的本部分的引用而成为本部分的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本部分,然而,鼓励根据本部分达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本部分。
GB l91包装储运图示标志EQV IS0 780:1997
GB 4793.1—1995测量、控制和试验室用电气设各的安全要求第1部分:通用要求IDT IEC61010—1:1990
GB/T6587.8 电子测量仪器电源频率与电压试验
GB/T7676.1—1998 直接作用模拟指示电测量仪表及其附件第1部分:定义和通用要求IDT IEC 60051—1:1984
GB/T 11463—1989 电子测量仪器可靠性试验
GB/T17949.1—2000 接地系统的土壤电阻率、接地阻抗和地面电位测量导则第1部分:常规测量
DL/T 475—1992 接地装置工频特性参数的测量导则
接地电阻 ground (earth) resistance
注:所谓远方是指一段距离,在此距离下,两个接地极的互阻基本为零。
电压(电位)极 voltage (electric potentilal) electrode
为获得测量接地电阻所需的电压(电位)量的接地导体。
为给大地注入测量接地电阻所需的测试电流的接地导体。
辅助接地电阻 auxiliary ground (erth) resistance
测量接地电阻时,作为电位端和电流端使用的辅助接地极和大地之间的电阻。
影响量的规定值和规定范围的一个适当集合,在此条件正规定仪表和/或附件的允许误差。
[GB/T 7676.1—1998中2.6.2.1]
[GB/T 7676.1—1998中2.6.2..]
标称使用范围 nominal range of use
影响量规定的一个取值范围。在此范围内,影响量所引起的改变量不超出规定值。
[GB/T7676.1一1998中2.6.2.3]
当一个单一影响量相继取参比条件的规定值和标称使用范围内任一点的值时,分别测量同一个量值的测量误差的最大差值(不考虑符号)。
a)A类:适用于一般接地装置接地电阻的测量(即常规测量);
b)B类:适用于大型接地装置接地阻抗的测量(即特殊测量)
0.1,0.2,0.5,1,2,5,10,20,50,100,200,500mA;
0.2,0.5,1.0,2.0,5.0,10.0。
按GB/T 6587.1规定的标称使用范围(工作范围)及流通条件分类,可分为II组、III组与1级、2级、3级。
个别影响量的标称使用范围(工作范围)可以低于规定组别的要求,但需符合企业标准规定,并在产品使用说明书标明。鼓励企业标准比规定组别的要求更严。
按被测量的显示(指示)方式分类,地阻仪分为模拟式和数字式。
注只涉及被测量的输出或显示的表示形式而与仪表的工作原理无关。
地阻仪的外表应整洁美观,不应有变形、缩痕、裂纹、划痕、剥落、锈蚀、袖污、变色等缺陷。文字、标志等应清晰、无误。
地阻仪的零件、部件、整件等应装配正确,牢固可靠。控制调节机构和指示装置应运行平稳,无阻滞和抖动现象。
地阻仪的测试端子的设置应符合GB/T17949.1或DL 475中接地电阻测试方法的要求。
地阻仪的安全性能应符合GB4793.1的有关规定。
地阻仪应能承受频率为50Hz,畸变系数不超过5兆的正弦交流试验电压lmin,而无击穿或飞弧,电晕放电效应和类似现象除外。
对工作电压不大于300V的地阻仪,试验电压值为2.3kV,
对工作电压大于300V的地阻仪,试验电压值按GB 4793.1的规定。
B类地阻仪的外表测试端子附近应有“当心电击危险”鳖告标志,其标志图形应符合GB4793.1—1995中表1的符号12。
B类地阻仪所附试验引线及其引线端子的绝缘强度应符合5.2.2,且与测试端子连接的引线端子不应是可触及件。
B类地阻仪测试电流的频率应利于准确测试大型接地装置的工频接地电阻包括其电阻分量和电抗,分量。
B类地阻仪测试电流的频率可不等于工频,但与工频50Hz的频率偏差不宜超过±l0Hz。
地阻仪类别 |
电阻测量范围Ω |
电感测量范围mH |
电容测量范围 F |
A类 |
1~2000 |
不规定 |
不规定 |
B类 |
0.01~20 |
0.1~100 |
1~100 |
c)供电电源:化学电源(额定值±0.2)V;交流电源(220±4.4)V,(50±0.5)Hz
e)等效辅助接地电阻:A类为(500±10)Ω;B类为(50±0.1)Ω;
模拟式地阻仪可以将测量范围是分为高准确度区段和低准确度区段,两区段之间应有分界标记或/和在产品使用说明书上注明其分界处的量值。高准确度区段的长度不得小于标度尺长度的50%。
在参比条件下,在规定的测量范围内,模拟式地阻仪的基本误差不超过表2规定的极限值。
表2 模拟式地阻仪基本误差极限值
模拟式地阻仪准确度等级 |
0.2 |
0.5 |
1.0 |
2.0 |
5.0 |
10.0 |
基本误差极限值 |
高准确度区段 |
±0.2 |
±0.5 |
±1.0 |
±2.0 |
±5.0 |
±10.0 |
低准确度区段 |
±0.5 |
±1.0 |
±2.0 |
±5.0 |
±10.0 |
±20.0 |
在参比条件下,在规定的测量范围内,数字式地阻仪的基本误差不超过按式(1)计算的基本误差极限值。式(1)中,变换系数a,固定误差b的值按表3确定。
表3 数字式地阻仪变换系数和固定误差值
数字式地阻仪准确度等级 |
0.2 |
0.5 |
1.0 |
2.0 |
5.0 |
10.0 |
变换系数a |
0.2 |
0.5 |
1.0 |
2.0 |
5.0 |
10.0 |
固定误差b |
1d |
1 d |
2 d |
2 d |
2 d |
4 d |
注:d——显示值最末位数的1个单位所对应的量值。 |
能同时模拟指示和数字显示的地阻仪应确定其中一种显示方式的示值符合规定的准确度等级。且两者示值之差不得超过该准确度等级所确定的误差极限值。
B类地阻仪电流测试端子Cl、C2(或E、C)之间,电压测试端子Pl、P2(或E)P)之间以及电流测试端子C与电压测试端子P之司均能承受频率为50Hz,畸变系数不超过5%的正弦交流试验电压lmin,地阻仪的准确度不致改变。
对工作电压不大于300V的地阻仪,试验电压值为其最大工作电压的4倍。
对工作电压大于300V的地阻仪,试验电压值为1.2kVo
B类地阻仪测试端子连接其测量范围外的阻抗(电阻、电感、电容)值而使地阻仪的测试电流达到仪器规定的额定值的1.2倍,或使地阻仪的测试电压达到仪器规定的额定值的1.2倍,地阻仪不致损坏。
由化学电源供电的地阻仪,当电源电压变化到其准确度等级可能改变时,应给出相应的电源电压指示或警告标志。
地阻仪的辅助接地电阻,由5.5.1的参比值改变至表4的规定值而引起的改变量应符合表4的规定。表4 辅助接地电阻引起的改变量
地阻仪类别 |
辅助接地电阻
Ω |
辅助接地电阻引起的改变量 |
A类 |
0,1000,2000 |
≤EL |
5000 |
≤2EL |
B类 |
0,10,20 |
≤EL |
100, 1000 |
≤2EL |
注:EL为地阻仪的基本误差极限值。 |
5.10 地电压引起的改变量地阻仪的测试端子施加表5规定的等效工频地电压而引起的改变量应符合表5的规定。表5 地电压引起的改变量
地阻仪类别 |
等效工频电压
V |
地电压引起的改变量 |
A类 |
2 |
≤EL |
5 |
≤2EL |
B类 |
5 |
≤EL |
10 |
≤2EL |
注:EL为地阻仪的基本误差极限值。 |
由化学电源供电的地阻仪,当电源电压为其标称使用范围(工作范围)上、下限值而引起的改变量;或由交流电源供电的地阻仪,当电源电压为(220±22)V,频率为(50±2.5)Hz而引起的改变量,不应使地阻仪的基本误差超过其基本误差极限值。
地阻仪的工作位置偏离规定的标准位置眪5。而引起的改变量应不超过其基本误差极限值的50片。
注:数字式地阻仪和装有水准器的地阻仪,不必进行由工作位置引起的改变量的试验。
地阻仪按4.4规定的组(级)别进行温度、湿度、振动、冲击和运输试验而引起的改变量均不碉过地阻仪的基本误差极限值。
地阻仪的平均无故障工作时间(MTBF)不小于1000h。
按5.2.2与GB4793.1—1995中6.8进行试验。
按5,2.4与GB4793.1—1995中6.2进行试验。
用测量误差不超过0.lHz、测量范围大于40Hz~60Hz的频率计检测。
在5.5.1的参比条件下,检测A类地阻仪的基本误差时用标准交流电阻箱为标准器,检测B地阻仪的基本误差时用标准交流电阻箱、标准电感、标准电容或标准阻抗作标准器。标准器的误极限值应不超过地阻仪准确度等级规定的基本误差极限值的l/4。等效辅助接地电阻为5.5.1的参比值。
模拟式地阻仪在测量范围内的每个有分度数字的分度线处检测。
数字式地阻仪在其有效测量范围内均匀选取至少10个测试值(包括测量范围的上限值、下限值或其附近处的值)处进行检测。
模拟式与数字式同时显示的地阻仪在模拟式地阻仪所检测的分度线处检测。
将标准器、等效辅助接地电阻按图1(三端子地阻仪)或图2(四端子地阻仪)所示的方式与地阻仪连接。
E—接地体端子;P—电压(电位)极端子;C—电流极端子;RE—标准器(等效接地电阻);RC、RP—等效辅助接地电阻图1 三端子地阻仪接线图Pl、P2—电压(电位)极端子;Cl、C2—电流极端子;RE—标准器(等效接地电阻);RP、RC—等效辅助接地电阻图2 四端子地阻仪接线图
调节标准交流电阻箱(或标准电感、标准电容、标准阻抗),使地阻仪的示值依次为按6.5.2确定的值BX,记录相应标准器的对应值BR。
按5.6电压试验后,在地阻仪测量范围的上限值、中点值、下限值或其附近处检测其基本误差。
按5.7负荷能力试验后,在地阻仪测量范围上限值、中点值、下限值或其附近处检测其基本误差。
用可调直流稳压电源模拟电池,用准确度等级不低于1.5级的直流电压表检测。
辅助接地电阻PR、RC分别为5.5.1的参比值和表4的各规定值时,在地阻仪测量范围的上限值、中点值、下限值或其附近处检测。
等效工频地电压值分别调至0V和表5的规定值时,在地阻仪测量范围的上限值、中点值、下限值或其附近处检测。
PV—l.5级低量限交流电压表;E—接地体端子;P—电压(电位)极端子;C—电流极端子;RE—标准器(等效接地电阻);RC、RP—等效辅助接地电阻图3 三端子地阻仪接线图
PV—l.5级低量限交流电压表;Pl、P2—电压(电位)极端子;Cl、C2—电流极端子;RE—标准器(等效接地电阻);RP、RC—等效辅助接地电阻图4 四端子地阻仪接线图
由化学电源供电的地阻仪,用可调直流稳压电源代替电池,分别将电源电压调节至5.11的规定时,在地阻仪测量范围的上限值、中间值、下限值或其附近处检测。
由交流电源供电的地阻仪,按GB/T 6587.8进行试验。
检测地阻仪基本误差时,在每个量程的上限值处,地阻仪处于前、后、左、右各倾斜5o位置检测。
按检验项目,地阻仪的缺陷分为A、B、C三类。A类为致命缺陷,缺陷等级数为l;B类为重缺陷,缺陷等级数为0.6;C类为轻缺陷,缺陷等级数为0.2。检验项目的缺陷类别见表6。缺陷类别为B类的项目,严重不符合技术要求时,允许将缺陷等级数判为1;缺陷类别为C类的项目,严重不符合技术要求时,允许按其不符合的程度将缺陷等级数判为0.6或1。
检验样本中,有缺陷检验项目的缺陷等级数之和小于1时判该样本合格;有缺陷检验项目的缺陷等级数之和不小于1时判该样本不合格。
鉴定检验在产品定型时进行。当地阻仪的主要设计、工艺、材料及元器件等有重大变更时或停产后恢复生产时也应进行鉴定检验。
检验中按7.3判别样本。样本全部合格,且现场使用试验合格方可判定鉴定检验合格。
鉴定检验结论对设计相同、规格不同的地阻仪均有效。应对出现缺陷可能性最大的那类地阻仪进行鉴定检验。检验中,出现故障,允许修复后再继续检验。
质量一致性检验在正式生产时进行,以判定所提交的地阻仪的质量是否符合产品标准的规定。
批量生产时,按表6的检验项目进行A组、B组、C组、F组试验。非批量生产时,按表6中序号1~12的检验项目进行全数检验,其合格判据按7.3。
表6 检验项目及其缺陷类别
序号 |
检验项目 |
本部分条款 |
缺陷类别 |
鉴定检验 |
质量一致性检验 |
技术要求 |
试验方法 |
A组 |
B组 |
C组 |
F组 |
1 |
外观与结构 |
5.1 |
6.1 |
C |
● |
● |
|
|
|
标志 |
8.1 |
6.1 |
C |
● |
● |
|
|
|
2 |
安全 |
5.2 |
6.2 |
A |
● |
|
● |
|
|
3 |
测试频率 |
5.3 |
6.3 |
C |
● |
|
● |
|
|
4 |
测量范围 |
5.4 |
6.4 |
B |
● |
|
● |
|
|
5 |
基本误差 |
5.5 |
6.5 |
A |
● |
● |
|
|
|
6 |
地电压反击 |
5.6 |
6.6 |
B |
● |
|
|
● |
|
7 |
负荷能力 |
5.7 |
6.7 |
B |
● |
|
|
● |
|
8 |
电源电压指示 |
5.8 |
6.8 |
B |
● |
|
● |
|
|
9 |
辅助接地电阻影响 |
5.9 |
6.9 |
B |
● |
|
● |
|
|
10 |
地电压影响 |
5.10 |
6.10 |
B |
● |
|
● |
|
|
11 |
供电电源影响 |
5.11 |
6.11 |
B |
● |
|
● |
|
|
12 |
工作位置影响 |
5.12 |
6.12 |
B |
● |
|
● |
|
|
13 |
温度试验 |
5.13 |
6.13.1 |
B |
● |
|
|
● |
|
湿度试验 |
5.13 |
6.13.2 |
B |
● |
|
|
● |
|
振动试验 |
5.13 |
6.13.3 |
B |
● |
|
|
● |
|
冲击试验 |
5.13 |
6.13.4 |
B |
● |
|
|
● |
|
运输试验 |
5.13 |
6.13.5 |
B |
● |
|
|
● |
|
14 |
可靠性试验 |
5.14 |
6.14 |
0.6 |
|
|
|
|
● |
15 |
现场使用试验 |
|
|
|
● |
|
|
|
|
注:●表示应检验的项目 |
A组检验是对生产的全部产品或一个检验比中的全部样本所进行的非破坏性试验,每批产品均按表6中A组检验规定的项目全数检验。样本的合格判据按7.3。
进行A组检验的批,其批质量以每百台的不合格品数表示。
每百台不合格品数不大于5的批,其批产品A组检验合格。A组检验中应对发现有缺陷的样本单位返修,合格后可以交货。
每百台不合格品数大于5的批,其批产品A组检验不合格,判为不合格的批,整批退回生产单位,找出原因,予以返修,重新检验。
B检验是对产品中较少受到工艺影响的性能特性实施的逐批检验。
在A组检验合格的产品批中,按GB/T 6593—1996中5.2.21抽样。安表6中B组检验的项目检验样本。检查水平S—3,合格质量水平AQL=6.5,合格判定安7.3与GB/T 6593—1996中的5.2.2.2。
在B组检验合格的产品批中,随机抽取3台,按表6中C组检验的项目进行试验。检验中,按7.3判别样本。样本全部合格,判定C组检验合格。试验过程中,出现故障允许修复后再检验。
C组检验,每年或每生产一定数量的地阻仪进行一次。或在设计、工艺有重大改变,有可能使产品性能不符合产品标准时进行。
按GB/T 6593—1996中5.2.6进行试验。
三端子地阻仪的测量端子附近应标出接地体端子标志符号“E”,电压(电位)极端子标志符号“P”和电流极端子的标志符号“C”。
四端子地阻仪的测量端子附近应标出电压(电位)极端子标志符号“P2”、“Pl”和电流极端子标志符号“C2”、“Cl”。
a)准确度等级标志,其标志图样应符合GB/T 7676.1—1998中表III一1的符号E-3;
b)水平使用或垂直使用标志,其标志图样应符合GB/T 7676.1—1998表III-1的符号D-l或符号D-2;
b)“易碎物品”、“向上”、“怕雨”等标志,标志图样应符合GBl91的规定;
地阻仪的包装应能防震、防潮。能使地阻仪经受5.13规定的运输试验而不致损坏。
地阻仪经包装后可用车、船、飞机等交通工具运输。但应避免暴晒、雨淋、水浸、跌落、撞击与机械损伤。
地阻仪可贮存在温度为-10℃~+50℃(II组)或-40℃~+60℃(III组),相对湿度不大于90%、无腐蚀性气体、通风良好的库房内。
中华人民共和国电力行业标准DL/T 845.3—2004
电阻测量装置通用技术条件第3部分:直流电阻测试仪General specifications for measuring resistance equipmentsPart3: DC resistance meters2004-03-05发布 2004-06-01实施中华人民共和国国家发展和改革委员会 发布
目 次
前言·······································································································································
1 范围·································································································································
2 规范性引用文件·············································································································
3 术语和定义·····················································································································
4 型号命名·························································································································
5 技术要求·························································································································
6 试验方法·························································································································
7 检验规则·························································································································
8 标志、标签、使用说明书·····························································································
9 包装、运输、贮存·········································································································
前 言
本标准根据原国家经济贸易委员会电力司《关于确认1999年度 电力行业标准制、修订计划项目的通知》(电力[2000]22号)下达的《电阻测量装置通用技术条件》标准项目制定。
DL/T845《电阻测量装置通用技术条件》本次发布以下四个部分:
本部分为DL/T845《电阻测量装置通用技术条件》的第3部分。
本标准参加起草单位:山东电力研究院、保定市精艺电子仪器有限公司、北京海淀三鑫测控新技术公司。
本部分主要起草人:王建、蔡崇积、李立生、张正平、李心恕。
电阻测量装置通用技术条件第3部分:直流电阻测试仪
DL/T 845的本部分规定了直流电阻测试仪(以下简称直阻仪)的定义、技术要求、试验方法、检验规则以及标志、标签、使用说明书、包装、运输、贮存。
本部分适用于采用四端钮伏安法测量原理,能直接显示感性负载、电气设备和材料的直流电阻测量值的电阻测试仪。
下列文件中的条款通过DL/T845的本部分的引用而成为本部分的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本部分,然而,鼓励根据本部分达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本部分。
GB l91 包装储运图示标志EQV ISO 780:1997
GB/T6587.8 电子测量仪器 电源频率与电压试验
GB/T 6593—1996 电子测量仪器质量检验规则
GB/T 11463—1989 电子测量仪器可靠性试验
直流电阻测试仪 D.C resistance tester
采用四端钮伏安法测量原理,能直接显示直流电阻值的一种仪器。
(显示装置的)分辨力 resolution(of a displaying device)
电流端钮 Cl、C2current terminal
电压端钮 Pl、P2 voltage terminal
表1 额定电流和测量范围
额定输出电流
A |
测量范围
Ω |
1 |
0~20 |
3 |
0~4 |
5 |
0~4 |
10 |
0~2 |
20 |
0~2 |
40 |
0~0.2 |
注:用户对产品的额定输出电流值和测量范围有特殊要求时,由供需双方协商决定。 |
准确度等级应符合如下系列:0.05、0.1、0.2。其各级别的等级指标、允许误差以及误差系数见表2。
表2 准确度等级别、允许误差以及误差系数
准确度级别 |
允许误差 |
误差系数 |
0.05 |
±0.05 |
≤0.05 |
0.1 |
±0.1 |
≤0.1 |
0.2 |
±0.2 |
≤0.2 |
在测量范围内,任一检定点的示值误差,应不大于允许误差。
在测量范围内,检定中最大绝对误差与量程满度值的比值的百分数为线性误差,应不大于允许误差。
在测量范围内,在规定的时间间隔内,其他条件保持不变,检定点示值相对于实际值的最大变化量,应不大于允许误差。
直阻仪在进行其测量范围上限电阻值测试时的实际输出电流值应不小于额定输出电流。
直阻仪在进行感性负载测量时应能有效,准确地测量出直流电阻值。对于设有自动判别锁定测量结果功能的直阻仪,应另外设置手动判别测量结果的功能。
直阻仪电源输入端对机壳之间的绝缘应能耐受频率为5OHz,1·5kV交流电压,历时lmin。试验期司不应发生闪络和击穿。
直阻仪完成免遭反电动势损坏的保护功能试验后,选取若千检定点重新进行示值误差试验。其示值误差应不大于允许误差。
产品及配套器件外观应完好,各转换开关和接线端钮的标记应齐全清晰、接插件接触良好、开关转动灵活、定位准确、外壳上应有明确可靠的接地端子。直阻仪上应有型号、名称、准确度级别、额定输出电流、测量范围、出厂编号、出厂日期、制造厂名等标记。
按GB/T 6587.8的规定,在电源频率为(50±l)Hz,电源电压为220(1±10%)V的工作条件下,其性能特性应符合产品标准的规定。
直阻仪应能承受GB/T6587.2组别为II的温度试验。
直阻仪应能承受GB/T6587.3中组别为II的湿度试验。
直阻仪应能承受GB/T6587.4中组别为II的振动试验。
直阻仪应能承受GB/T6587.5中组别为II的冲击试验。
直阻仪应能承受GB/T6587.6中组别为II的运输试验。
直阻仪的平均无故障时间(MTBF)应不小于1000h。
直阻仪的示值误差试验用四端钮过渡直流标准电阻作为标准器进行检定。
b)标准器的允许误差绝对值应小于直阻仪允许误差绝对值的1/4;
d)标准器的午稳定性应小于被检直阻仪的允许误差绝对值的1/10。
a)在基本量程内均匀选取十个检定点进行示值误差检定;
b)在非基本量程内选取上、中、下三个检定点进行示值误差检定。
注:基本量程为测量仪器不经过量程变换器直接接入的量程。
稳定性误差试验在最小量程进行,在规定的测量时间30min内,每隔5min记录一次数据,计算其最大变化量。
直阻仪的最小分辨力在最低量程档进行测定。通常采用在一个低值电阻上并联一个较大的电阻,使其电阻的变化等于要测的分辨力。
将直阻仪的交流供电电源调置198V,直阻仪的输出端接入电阻性负载,使负载电流等于额定输出电流,用标准电流表测量输出端的电流值。试验时应选择额定输出电流的平万与该量程测量范围的上限值的乘积为最大来进行该项试验。
直阻仪在进行感性负载特性试验时,可采用测量实物电感或模拟电感方式进行。
按GB/T6587.7的试验程序进行。直阻仪处于非工作状态。开关置于接通位置,测量电源端子机壳的绝缘电阻。电源端子对机壳的绝缘电阻使用500V的绝缘电阻表进行试验。
用输出电压不低于2000V的工频耐压装置在电源输入端与机壳之间施加1.5kV电压,历时1min。
直阻仪输出端接入感性负载进行测量,当测量进行一段时间时突然人为拿开电流夹具,以此产生反电动势考核直阻仪保护功能。
根据5.7的要求,按GB/T6587.2第2章规定的试验要求和第3章规定的试验方法进行。
根据5.8的要求,按GB/T6587.3第2章规定的试验要求和第3章规定的试验方法进行。
根据5.9.1的要求,按GB/T6587.4第2章规定的试验要求和第3章规定的试验方法进行。
根据5.9.2的要求,按GB/T6587.5第2章规定的试验要求和第3章规定的试验方法进行。
根据5.9.3的要求,按GB/T6587.6第2章规定的试验要求和第3章规定的试验方法进行。
按GB/T11463—1989表1定时定数截尾试验方案1-1的规定进行。依据可靠性试验方案主要失效判据的规定,做出可靠性试验判决。
产品检验分型式检验、出厂检验、常规检验。检验项目见表3。
表3 检验项目
序号 |
检验项目 |
型式检验 |
出厂检验 |
常规检验 |
1 |
外观检查 |
√ |
√ |
√ |
2 |
示值误差 |
√ |
√ |
√ |
3 |
线性误差 |
√ |
√ |
√ |
4 |
稳定性误差 |
√ |
√ |
√ |
5 |
最小分辩力试验 |
√ |
√ |
|
6 |
额定输出电流试验 |
√ |
√ |
|
7 |
感性负载试验 |
√ |
√ |
√ |
8 |
绝缘电阻试验 |
√ |
√ |
√ |
9 |
介电强度试验 |
√ |
√ |
√ |
10 |
消弧功能检验 |
√ |
√ |
√ |
11 |
免遭反电动势损坏的保护功能检验 |
√ |
√ |
√ |
12 |
温度试验 |
√ |
|
|
13 |
湿度试验 |
√ |
|
|
14 |
振动试验 |
√ |
|
|
15 |
冲击试验 |
√ |
|
|
16 |
运输试验 |
√ |
|
|
17 |
可靠性试验 |
√ |
|
|
型式试验的目的在于检验产品设计的合理性和在本技术条件下适应性。
c)iE式生产时,定期或累计一定产量后(周期和数量由企业标准规定);
d)正式投产后,如设计、工艺材料、元器件有较大改变,可能影响产品性能时;
f)国家技术监督机构或受其委托的技术检验部门提出型式检验要求时;
型式试验的抽样与判定按GB/T6593的要求进行。
出厂试验的目的在于检验产品制造过程中的缺陷和测量准确度。
直阻仪所测数据直接影响电力系统安全运行,使用中的直阻仪必须每年检验一次。以保证直阻仪
每台直阻仪必须在机箱的显著位置设置持久明晰的标志或铭牌,标志下列内容:
直阻仪的使用说明书应给出如何安全私正确地使用本设备的全部信息。其信息应包括下列内容:
d)包装箱外面书写“防潮”、“向上”、“小心轻放”等字样。
应在产品的标准中规定包装、运输、贮存要求或引用有关的包装、运输、贮存标准。
a)产品的合格证(产品合格证的编写应符合GB/T14436的规定)和技术文件、附件、备品、各件齐全;
产品应有内包装和外包装,可动部分应锁紧扎牢,包装应有防尘、防雨、防水、防潮、防振等措施。
产品应适于陆运、空运、水运(海运)。运输装卸按包装箱上的标志进行操作。
包装完好的直阻仪应满足GBl91条款规定中的贮存运输要求。长期不用的直阻仪应保留原包装,在相对湿度不大于85兆的库房内贮存,室内无酸、碱、盐及腐蚀性、爆炸性气体和灰尘以及雨、雪的侵害。
中华人民共和国电力行业标准DL/T 845.4—2004
电阻测量装置通用技术条件第4部分:回路电阻测试仪General specifications for measuring resistance equipmentsPart4: loop resistance measurement testor2004-03-05发布 2004-06-01实施中华人民共和国国家发展和改革委员会 发布
目 次
前言·······································································································································
1 范围·································································································································
2 规范性引用文件·············································································································
3 术语和定义·····················································································································
4 产品型号命名·················································································································
5 技术要求·························································································································
6 试验方法·························································································································
7 检验规则·························································································································
8 标志、包装、运输和贮存·····························································································
参考文献·······························································································································
前 言
本标准根据原国家经济贸易委员会电力司《关于确认1999年度电力行业标准制、修订计划项目的通知》(电力[2000]22号)下达的《电阻测量装置通用技术条件》标准项目制定。
DL/T845《电阻测量装置通用技术条件》本次发布以下四个部分:
本部分为DL/T845《电阻测量装置通用技术条件》的第4部分。
本标准参加起草单位:山东电力科学院、北京海淀三鑫测控技术公司。
本部分主要起草人:陈轩恕、李心恕、王勤、蔡崇积、李立生。
电阻测量装置通用技术条件第4部分:回路电阻测试仪
DUT845的本部分规定了回路电阻测试仪(下称回路仪)的技术要求、试验万法、检验规则及标志、包装、运输和贮存。
本部分适用于回路电阻测试仪的设计、制造和检验、验收。
下列文件中的条款通过DL/T 845的本部分的引用而成为本部分的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本部分,然而,鼓励根据本部分达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本部分。
GB l91包装储运图示标志EQV ISO 780:1997
GB 4793.1 测量、控制和试验室用电气设各的安全要求 第一部分:通过要求IDT IEC61010-1:1990
GB/T 6587.8 电子测量仪器电源频率与电压试验
GB/T 6593—1996 电子测量仪器质量检验规则
GB/T 11463—1989 电子测量仪器可靠性试验
影响量的规定值和规定范围的一个适当集合,在此条件下规定仪表和/或附件的允许误差。每个影响量均可有参比值或参比范围。
标称使用范围 nominl range of use
对影响量规定的一个取值范围。在此范围内影响量所引起的改变量不超出此规定值。
回路仪的测量范围为0μΩ~1999μΩ;其分辨力为1μΩ。
测量准确度等级应符合如下系列之一:0.2,0.5,1.0,2.0。
在测量范围内,任一检定点的示值误差应不大于允许误差。
在测量范围内,检定点中最大绝对误差与量程满度值的比值的百分数为线性误差,检定点中线性误差应不大于允许误差。
在测量范围内,在规定的时间间隔内,当其他条件不变时,检定点中读数相对于实际值的最大变化量应不大于允许误差。
在测量范围内,在规定的参比条件下,回路仪的最小电流维持时间应不低于1min。
5.1.3.7 回路仪的准确度等级、允许误差和误差系数
回路仪的准确度等级、允许误差和误差系数对应于表1。
回路仪外框表面不应有明显的凹痕、划伤、裂缝和变形等现象,表面镀涂层不应起泡、龟裂和脱落。金属零件不应有锈蚀及其它机械损伤。
回路仪应进行温度、湿度、振动、冲击、运输方面的试验,试验完后回路仪应能正常工作,满足5.1的要求。
表1 回路仪的准确度等级、允许误差和误差系数
准确度等级 |
允许误差( ) % |
误差系数(a+b) % |
0.2 |
±0.2 |
≤0.2 |
0.5 |
±0.5 |
≤0.5 |
1.0 |
±1.0 |
≤1.0 |
2.0 |
±2.0 |
≤2.0 |
a)回路仪供电电源:AC 220×(1±10%) V:50×(1±5%)Hz;
回路仪交流电源引线端与外壳之间的绝缘电阻不应小于20MΩ。
回路仪交流工作电源引线端与外壳之间承受1.5kV 频交流电压1min时,应不出现飞孤和击穿现象。
回路仪的平均无故障工作时间(MTBF)应不小于1000h。
在本标准中,除环境试验以外,其他试验均在下述大气条件下进行:
用目测法及手感法检查,以上各项试验后回路仪均符合5.2的要求。
负载能力:在负载为2000μΩ时,调节电流源能否到达回路仪电流源输出;对输出电流不可调的回路仪同时监视负载电压,测试回路仪工作电流下的负载能力。
在参比条件下,在回路仪的标称使用测量范围内进行检定,采用四线连接法利用直流标准电阻器法进行。用直流标准电阻器的示值同采用四线连接法测量的回路仪读数进行比较,确定回路仪的基本误差。检定用直流标准电阻器准确度级别高于被检回路仪标称准确度级别二级,并且直流标准电阻器的允许电流应不低于被检回路仪的工作电流。
对0μΩ~1999μΩ作全量程检定,均匀选取10个点进行测量。记录每个检定点的显示值(读数),与对应标准器的标准值的差值为示值误差。所有检定点的示值误差应符合5.1.3.3的要求。
对所有检定点的线性误差应符合5.1.3.4的要求。
在规定的测量时间内(1min),最大检定点的稳定误差应符合5.1.3.5的要求。
在负载为2000μΩ时,回路仪的最小电流维持时间应符合5.1.3.6的要求。
受试产品分别施加电源电压为198V、220V、242V三种情况,及电源电压保持220V,频率分别置于47.5Hz和52.5H7,按照GB/T6587.8要求进行,回路仪应符合5.1的要求。
进行温度、湿度、振动试验时,受试产品应在不加任何防护包装状态下进行。进行运输试验时,受试产品应在完整包装状态下进行。
进行本项试验时,将回路仪置于高温试验箱中,按GB/T6587.2—1986试验方法中第II组进行。试验完后,回路仪符合5.3的要求。低温试验时为防止凝露,可用塑料薄膜密封。
进行本项试验时,将回路仪置于潮湿试验箱中,按GB/T6587.3—1986试验方法中第II组进行。试验完后,回路仪应符合5.3的要求。
本项试验按GB/T6587.4的试验方法第II组进行。试验完后,回路仪应符合5.3的要求。
本项试验按GB/T6587.5的试验方法第II组进行。试验完后,回路仪应符合5.3的要求。
本项试验按GB/T6587.6的试验方法第II组进行。试验完后,回路仪应符合5.3的要求。
按GB何4793.1中基本绝缘电子测量仪器的要求,结果应符合5.5.1的要求。
将短接后的电源与外壳之间施加有效值为1.5kV的工频交流电压,时间为lmin,试验结果应符合
按照GB/T11463—1989中定时定数截尾中1-1号方案进行,结果应符合5.6的要求。
检验的试验项目分出厂检验、型式检验和常规检验,见表2。
表2 各类检验的试验项目和方法
试验项目 |
技术要求 |
试验方法 |
出厂检验 |
型式检验 |
常规试验 |
外观 |
5.2 |
6.2 |
√ |
√ |
√ |
环境试验 |
5.3 |
6.5 |
|
√ |
|
电源适应性 |
5.4 |
6.4 |
|
√ |
√ |
性能要求 |
5.1 |
6.3 |
√ |
√ |
√ |
安全 |
绝缘 |
5.5.1 |
6.6.1 |
√ |
√ |
√ |
耐压 |
5.5.2 |
6.6.2 |
√ |
√ |
√ |
可靠性 |
5.6 |
6.7 |
|
√ |
|
注:表中“√”表示必须做的项目。 |
出厂检验须逐台进行,回路仪出现某项不合格即为不合格品,不合格品应做出标记。检验合格的产品,出厂时应附产品合格证。
型式检验是对回路仪质量进行全面的考核,应从出厂检验合格的产品中随机抽取。在下列情况之一时应做型式检验:
型式检验的样品数不得少于2台。进行型式检验时,回路仪出现某个项目不合格,应加倍抽样进行该项检验。若仍不合格,则判定受检产品不合格。
常规检验是应客户要求,在使用过程中根据表2要求进行。
b)包装箱内应附有关配件、产品合格证、质检证书、使用说明书、产品装箱清单;
c)“小心轻放”、“向上”和“怕湿”等标志,应符合GBl91的规定。
运输过程中不得置于露天车厢,应防雨、防尘、防机械损伤。
存放产品的库房环境温度:0℃~40℃,相对湿度不大于80%,室内无腐蚀气体,不受灰尘、雨雪侵害,无强烈的机械振动和冲击。产品应平放。
参 考 文 献
ICE694—1990 高压开关设备和控制设备标准的共用条款
|